TOP > Various Settings of the Product > The Product's [Settings] Menu > [Applications] Menu > [Applicator] > [Apply Adjustment] > [Conveyor Speed] [Conveyor Speed] Set the speed of the conveyor. • This changes the settings of the product, this function does not change the speed of the actual conveyor. The setting range is from 1 to 200. Set the [Conveyor Speed] and [Product Length], and then calculate the timing to mask the [Activate Apply] signal or the [Activate Apply (Level)] signal. The activate signal is masked during application operations at 1 m/min (3.28 feet/min). • The mask timing is the time for the package to pass, which is calculated from the length of the package. During the time, the package detection sensor does not detect the package until it passes. Performance overload is not detected during this time. Related Topics Setting Value Input or Selection Back to top